Medivators DSD-201 Parts Guide

DSD201-water-filters-air-filters

OEM-Compatible Filters, PM Kits, and Replacement Parts Guide

Two decades in service, and plenty of these dual-basin units are still earning their floor space. Keeping one running comes down to sourcing the right filters, the right PM kit, and the right valve, ordered by the right number. This guide walks through what fits the 201, which numbers to put on the PO, and the mix-ups that cause return shipments. MedService Repair supplies OEM-compatible parts, PM kits, AER filters, and refurbished units for Medivators automated endoscope reprocessors nationwide at a discount against OEM lists, with free over-the-phone tech support when you're not sure what you're looking at.

Medivators DSD-201 and STERIS DSD-201 Parts: One Machine, Four Brand Names

DSD201 AER automatic endoscope reprocessor

Same machine, four names on the paperwork. Medivators built it. Minntech owned Medivators. Cantel Medical absorbed Minntech, and STERIS bought Cantel in 2021. The logo changed hands; the machine never did. Search under either brand, and you land in the same catalog with the same numbers: the annual PM Kit is still #78400-722, the Air Filter Assembly is still #MF01-0028, and the Disinfectant Pump is still #78400-689. Nothing was renumbered along the way. One note: the 201 is a dual-basin endoscope reprocessor, a different machine from the newer EDGE and the Advantage Plus. Both get covered near the end of this guide.

Medivator, Cantel, or STERIS on the Label: The Part Numbers Don't Change

Half the calls we take start with "my Medivator" — singular, no S. That's fine. Medivator, Medivators, Cantel, STERIS: Whatever badge is on your front panel, the part numbers underneath are identical. A unit labeled Cantel takes the same kits and filters as one labeled Medivators. Order by OEM part number, and the badge era is irrelevant.

DSD-201 Filters by Micron Rating: Which Filter Goes Where

The DSD-201 endoscope reprocessor filters at four points: the air line, the disinfectant line, and a two-stage incoming water line. Order the wrong filter and it either won't fit or won't protect the line it's on. Replacement intervals have no universal calendar; they depend on your water quality and cycle volume, so follow the IFU and your facility's policy. Holding a cartridge and not sure which one it is? Call us. The lookup is free.

Air Filter Assembly and Disinfectant Filter Assembly (0.2 Micron and 65 Micron)

Two canister assemblies, easy to confuse until you learn the color code. The Air Filter Assembly, OEM #MF01-0028, protects the air compressor line: 0.2 micron, blue inlet, and white outlet. Its 65-micron counterpart on the disinfectant line is OEM #MF01-0011: red inlet, grey outlet. Catalog pages skip the colors, but they're the at-a-glance tell when you're standing at the machine. Blue and white air. Red and grey disinfectant.

Water Line Prefilters: The 1 Micron Prefilter and 0.45 Micron Absolute Prefilter Cartridge

Incoming water gets cleaned in stages before it ever reaches a basin. Stage one is the 1-micron Prefilter, OEM #MF01-0014 — the coarse element that catches sediment and particulate. Stage two is the 0.45 micron absolute cartridge, OEM #MF01-0015, which polishes what stage one lets through. The order matters. The cheap coarse element takes the abuse so the finer cartridge lasts its full life. Neglect the first stage and you'll burn through #MF01-0015 cartridges faster than your budget likes.

DSD-201 Replacement Parts by Category: Valves, Pumps, Tubing, and Sensors

DSD201 replacement parts

Beyond filters, most of what wears out on the endoscope reprocessor falls into four buckets: valves, pumps, tubing, and sensors. Everything below is OEM-compatible, priced below OEM list, and ordered by OEM part number, which is the only reliable way to guarantee fit.

Valves and Valve Rebuild Kits

Valve rebuild kits are what keep twenty-year-old units out of the scrap line. Three cover the drain path: Drain/Return #78400-658, Overflow #78400-659, and the Basin Valve Rebuild Kit #78400-660. Backflow trouble usually points to the Check Valve #78401-260 or the Alcohol/Detergent Check Valve #MV01-0040. Air-side cycling faults often trace to the Solenoid Valve (MAC) #41600-109. If the solenoid valve clicks but won't actuate cleanly, try the coil, #MTC032, before replacing the whole thing. The Block Valve #41600-123 rounds out the list.

Pumps and Peristaltic Pump Tubing

Two classic wear items here. The Disinfectant Pump #78400-689 runs on 115 VAC, 60 Hz, and when it quits, cycles stop; high-volume departments keep a spare on the shelf. The Peristaltic Pump Tubing Set #MT010-0500 is the other because peristaltic tubing fatigues on schedule no matter how gently the machine runs. Both stay available as OEM-compatible replacements at a discount compared to the OEM list.

Sensors, Clamps, Connectors, and Fittings

Small parts stop more cycles than big ones. The Basin Sensor Cover #MC13-0015 (also listed as MTC029) protects the level sensor that tells the unit its basin is full. The KWIK Clamp #RXC021 and Male Push-In Connector #RXF015 handle line connections. Retaining Compound 609 #RXA048 locks down fittings that vibration keeps loosening. Cheap items. Order spares with your next kit.

Sourcing Parts for Discontinued Endoscope Reprocessors: Keeping the DSD-201 Running

Here's the part the OEM won't put in a brochure: STERIS has service-matured the 201 and steers buyers toward its successor. Factory parts and factory service are winding down. Your unit isn't done, though. Third-party compatible parts are how facilities keep discontinued automated endoscope reprocessors in service years past end-of-life, and every part number in this guide is stocked. Weighing repair against replacement? That's a different decision about a different machine; our DSD EDGE parts page covers the successor.

Annual PM Kits for the DSD-201: #78400-722 vs. #78400-724

dsd 201 pm kit

Two annual kits, and the difference matters. PM Kit #78400-722 (RPI #MTK009) fits units upgraded to the 3/4-inch drain valve, or serial #649904-064 and higher. PM Kit #78400-724 covers earlier configurations and includes Drain Valve #78401-050 in the box. So before ordering: pull your serial number and check which drain valve you're running. Two minutes of checking beats a week waiting on a return. Can't tell? Call our free tech support line with the serial, and we'll confirm the kit on the spot. The procedure itself lives in our preventative maintenance post; this section is only about which kit to buy.

OEM-Compatible Parts vs. OEM: Warranty, IFU, and Policy Checks

Compatible parts are built to fit and function in your endoscope reprocessor at a real discount against OEM list. That's the pitch, and it's honest. But so is this: warranty and regulatory situations vary by facility. Before switching from OEM-sourced components, check the IFU, your biomed department's policy, and any service contract still in force — some contracts specify OEM part sourcing. Ordering by OEM part number takes fit off the worry list, and if a fit question comes up anyway, the phone call costs nothing.

Parts for Other Machines: Medivators DSD EDGE and Advantage Plus

Running an EDGE or an Advantage Plus instead? Different machines, different parts, different pages. Nothing in this guide crosses over: the EDGE is the 201's successor with its own filter lineup, and the Advantage Plus is its own platform entirely. Head to our DSD EDGE parts page for the former and our Medivators parts article covering the Advantage Plus for the latter.

Order Medivators DSD-201 Parts with Free Phone Tech Support

DSD201 Parts Free Support

MedService Repair ships nationwide, stocks the numbers in this guide, and prices them below the OEM list. Refurbished 201 units are on hand for machines past saving. And the differentiator no catalog site matches: free over-the-phone troubleshooting before and after the sale. Unsure whether your serial takes the -722 or the -724 kit? Reading a worn label and guessing at the number? Call. We'll confirm the part while you're standing at the machine. Then order your DSD-201 parts and get your basins back in rotation.

0
Medivators DSD Edge Parts Guide

Related Posts